In Chile odour issues are becoming critical. The community is putting pressure on authorities and industry is being forced to take actions in order to minimize odour nuisances. There are approaches that allow delivering "reliable" results<
E. Contreras y V. Zorich M.
Ecometrika, Américo Vespucio 2296, Conchalí, Santiago, Chile. www.ecometrika.com, econtreras@ecometrika.cl, vzorich@ecometrika.cl.
Keywords: Belgian plume method, odour exposure impact assessment, odour control master plan.
Abstract
In Chile odour issues are becoming critical. The community is putting pressure on authorities and industry is being forced to take actions in order to minimize odour nuisances. There are approaches that allow delivering "reliable" results such as odour dispersion modelling, yet the question remains on how reliable the result of modelling can be. Are the results of modelling a true representation of the real odour impact and –most importantly– nuisances? In order to check the results obtained from a dispersion model, and validate how representative they are, it is essential and necessary to verify these. In this paper two case studies are presented that illustrate how methodologies by panel field can validate parallel modelling approaches. In both case, validation process was a valuable tool for detecting errors and obtaining reliable results. We conclude that modelling results must be validated by another methodology or they can be clearly misleading.
- Find this article in other languages:
- Deutsch
- French
- Español
- Polski
- اللغة العربية
If you find this article interesting, you might be also interested in these articles.
- Official program of the Conference on Environmental Odour Management in Madrid, 27-28 Nov 2012
- Monitoring the biofiltration of α-pinene vapours through municipal solid waste and pruning residues composts using an e-nose
- Evaluation of capacity of a TD-GCO-MS system in air sample analysis
- 5th IWA Odour and Air Emissions Conference Jointly Held With 10th Conference on Biofiltration for Air Pollution Control. March 4 – 7, 2013, San Francisco, California, USA
The Edmonton Waste Management Centre (EWMC) of Edmonton, Alberta, Canada, is a unique collection of advanced waste processing and research facilities. Owned and operated by the city of Edmonton Waste Management Services, the EWMC is an integral part of Edmonton’s sustainable approach to waste management. The Centre is 233 hectares in size – 25 hectares is devoted to their composting facility, and is the largest of its kind in North America.
Knowing the chemical composition of an air sample is a complex challenge because the abundance of substances of different nature and different concentrations. This complexity increases if we want to identify those compounds that cause odors, since many of them are present at very low concentrations, hardly detectable by more conventional instrumental systems. Gas Chromatography (GC) coupled at Mass Spectrometry (MS) GC-MS, is undoubtedly the more robust and consolidated technique in air sample analysis. The more common types of GC-MS are Mass Spectrometers with single quadrupole detector. However, the continuous technological development of analytical instrumentation and especially in Mass Spectrometry allows ever more robust analyses, more sensitive and with improved resolution. In recent years, the interest in GC-TOFMS systems (TOF: time-of-flight) has been increasing, because it involves a faster detector with higher sensitivity and resolution compared to the conventional single quadrupole GC-MS. This paper compares a GCO-TOFMS system recently acquired by Odournet to a more conventional GC-MS quadropolemethod. Both used thermal desorption (TD) for the chemical and sensory analysis of air samples collected in the output of biofilters. The presented results show a clear difference in terms of sensitivity and resolution for GC-TOFMS compared to a conventional GC-MS identifying almost50% more compounds in the same air sample. Additionally an analysis using GCO (GC-sniffing) was performed, showing good complementarity with the results obtained by GC-TOFMS for the same sample.