Valdenebro   The RAMS-CALMET-CALPUFF modelling system has been used to simulate the odorous impacts from a paper-mill in an urban area located several kilometres away in a coastal mountainous area.

   Over the last years, episodes of citizens complaints due to malodours have been registered, with a potential origin in several pollution sources located inside and outside the city. A selection of episodes under anticyclonic conditions, with poor ventilation in general and continuous changes of stability and wind during the day, has been simulated.

V. Valdenebro1*, E. Sáez de Cámara1, G. Gangoiti1, L. Alonso1, J. A. García1, M. Navazo2, M. de Blas1, J. Lavín3, N. García-Borreguero


1Universidad del País Vasco UPV/EHU, Escuela de Ingeniería de Bilbao, Alameda de Urquijo s/n, 48 013 Bilbao, España.
2Universidad del País Vasco UPV/EHU, Escuela Universitaria de Ingeniería de Vitoria-Gasteiz, C/ Nieves Cano 12, 01006 Vitoria-Gasteiz, España.
3 Sociedad Española de Abastecimientos, S.A., Gran Vía Marqués del Turia,¸19, 46005, Valencia, España.
4Gobierno Vasco, Departamento de Medio Ambiente y Política Territorial, Dirección de Administración Ambiental, Servicio de aire, Donostia-San Sebastián 1, 01010 Vitoria-Gasteiz, España.
 * veronica.valdenebro@ehu.eus

scentroid sm100 kit   The SM100i uses fixed orifice dilution control and therefore requires minimal re-calibration. However standard, annual re calibration should be performed. As a new service for their clients, the company Scentroid offers their new maintenance Service that includes disassemble and ultrasonic cleaning, re-assembly and replacement of all tubing and seals and a final re-calibration.

   The parts that should be sent for calibration are the dilution System of SM100 (or the retrofit Kit for SM100i), the Face Mask, the carbon filter with the tank valve and all the plates. The annual service and recalibration includes the following:

sesion06 ramos05   The aim of this work is to present a system to monitor odour incidents to detect odour sources in industrial areas that can cause an odour impact in residential neighbourhoods.

   The area of this study is located between two very important spots of chemical Industrial areas in the port of Tarragona, in the northeast of Spain. Nearby these two industrial areas there are 3 fire stations. In this study, the firemen were trained to perform odour field inspections by means of an android app. In addition, the odour performance of the odour inspectors was also evaluated.

P. Ramos* and P. Pindado

Centro Tecnológico de la Química de Catalunya CTQC, Calle Marcel•lí Domingo, s/n (edifici N5) Campus Sescelades, 43007 Tarragona (Spain)
pablo.ramos@ctqc.org

All the content here under Creative Commons license